00723
Patillas zona urbana, PR
PATILLAS URBANO

Is Patillas zona urbana tap water safe to drink?

Higher concern
Last tested: January 2025
Source: Official EPA UCMR5 federal monitoring data. Last tested January 2025.
Townships:
  • Muñoz Rivera barrio, PR
  • Mulas barrio, PR
  • Marín barrio, PR
  • Jacaboa barrio, PR
  • Quebrada Arriba barrio, PR
  • Pollos barrio, PR
  • Guardarraya barrio, PR
  • Ríos barrio, PR
  • Cacao Bajo barrio, PR
Places:
  • Palmas comunidad, PR
  • Lamboglia comunidad, PR

The short answer for Patillas zona urbana

Patillas zona urbana tap water has 8 contaminants above EPA guidelines, including 6:2 FTS at 5.7× the limit (tested January 2025). See the full compound-by-compound breakdown and filter recommendations.

The health risk for Patillas zona urbana

PFAS ('forever chemicals') have been detected above EPA limits in this water system's most recent tests. These synthetic chemicals do not break down in the body and are linked to a range of health effects. A certified filter is strongly recommended.
  • 6:2 FTS, PFBS, PFDA, PFOS above limit.
6:2 FTS concentration (µg/L) January 2025
0 µg/L 0.005 µg/L 0.05 µg/L
0.029 µg/L
Detected
µg/L
0.005 µg/L
EPA limit
guideline
472% above limit
Comparison
vs. guideline
EPA limit: 0.005 µg/L | Your water: 0.029 µg/L
Certified Filters for Patillas zona urbana Tap Water

6:2 FTS (a PFAS 'forever chemical') was detected above EPA limits. These filters are independently certified to reduce common drinking-water contaminants.

Water filter recommendation for Patillas zona urbana tap water: Epic Pure XP Water Filter Pitcher
Pitcher filter
Epic Pure XP Water Filter Pitcher
NSF-certified dual-layer filtration reduces 70+ contaminants including PFAS, lead, chlorine, microplastics, and bacteria.
NSF/ANSI 42, 53, 401 & P473Removes 99.99% PFASMade in USABPA-free
Most elevated compounds
Compound Measurement EPA Limit Comparison
6:2 FTS
Tested: January 2025 · PF PATILLAS URBANO
0.029 µg/L 0.005 µg/L 472% above limit
6:2 FTS
Tested: January 2025 · PF PATILLAS URBANO
0.029 µg/L 0.005 µg/L 472% above limit
PFBS
Tested: October 2024 · PZ YAUREL 1
0.012 µg/L 0.003 µg/L 297% above limit
PFOS
Tested: October 2024 · PZ YAUREL 1
0.014 µg/L 0.004 µg/L 258% above limit
PFDA
Tested: October 2024 · PZ TEXACO WELL
0.005 µg/L 0.003 µg/L 83% above limit
View all tested compounds

PZ BELINDA · Tested: October 2024

Compound Measurement EPA Limit Comparison
PFOS 0.007 µg/L 0.004 µg/L 72% above limit
PFBS 0.004 µg/L 0.003 µg/L 43% above limit
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

PZ TEXACO WELL · Tested: October 2024

Compound Measurement EPA Limit Comparison
PFDA 0.005 µg/L 0.003 µg/L 83% above limit
PFOS 0.004 µg/L 0.004 µg/L 7% above limit
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

PZ YAUREL 1 · Tested: October 2024

Compound Measurement EPA Limit Comparison
PFBS 0.012 µg/L 0.003 µg/L 297% above limit
PFOS 0.014 µg/L 0.004 µg/L 258% above limit
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

PF PATILLAS URBANO · Tested: January 2025

Compound Measurement EPA Limit Comparison
6:2 FTS 0.029 µg/L 0.005 µg/L 472% above limit
6:2 FTS 0.029 µg/L 0.005 µg/L 472% above limit
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

PZ ARROYO 1 · Tested: October 2024

Compound Measurement EPA Limit Comparison
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

PZ YAUREL 2 · Tested: October 2024

Compound Measurement EPA Limit Comparison
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Water utilities serving ZIP 00723

Service area boundaries are approximate and based on state filings or modeled estimates. Contact your utility to confirm exact service at a specific address.

Modeled boundaries are shown with a dashed outline. Outlines appear when service-area boundary data is available for this ZIP.

Frequently Asked Questions about ZIP 00723 Tap Water

What contaminants are above EPA limits in ZIP 00723?

ZIP 00723 has 8 contaminants above EPA health guidelines in the latest available data, including 6:2 FTS at 5.7x the EPA guideline. The full table on this page lists every tested compound and its measured level.

Will boiling ZIP 00723 tap water remove 6:2 FTS?

Boiling tap water can kill many pathogens, but it does not remove most chemical contaminants tracked in EPA monitoring. Several dissolved contaminants can even concentrate as water evaporates. For the chemical contaminants reported in ZIP 00723, a certified filter is more reliable.

Do basic pitcher filters remove 6:2 FTS?

Basic pitcher filters are typically rated for chlorine, taste, and odor (NSF/ANSI 42), not for the broader list of contaminants tracked in EPA monitoring. Match the certification (NSF/ANSI 42, 53, 58, or P473) to the specific compounds listed in this report before assuming a filter helps.

Who provides tap water in ZIP 00723?

Public records identify PATILLAS URBANO as a primary water system associated with ZIP 00723. Service boundaries can vary by address, so confirm exact service with the utility.

When was ZIP 00723 tap water last tested?

The most recent test date used in this report is January 2025. EnviroClarity last refreshed this page on 2026-05-05.

Where can I find the official water quality report for ZIP 00723?

Every U.S. public water system is required to publish an annual Consumer Confidence Report (CCR). Contact PATILLAS URBANO or visit their website for the latest official report covering ZIP 00723. The EPA also maintains a national CCR locator.

Primary source EPA UCMR5 (2023-2025)
Guideline source EPA drinking water standard (6:2 FTS: 0,005 µg/L)
Last tested January 2025
Last page update 2026-05-05

Check another ZIP code

    Data reflects publicly reported utility records from EPA datasets and local utility disclosures. This information is educational and not medical advice.

    Protect your water in Patillas zona urbana → see certified filters