70760
New Roads, LA
NEW ROADS WATER SYSTEM

Is New Roads tap water safe to drink?

Higher concern
Last tested: September 2025
Action Advised
Source: Official EPA UCMR5 federal monitoring data | Last tested September 2025

Can you drink the tap water in New Roads?

New Roads tap water has lithium above EPA guidelines at 1,2× the limit (tested September 2025). See the full report with all tested compounds and filter options.

Recommended for New Roads tap water
Water filter for New Roads tap water: Epic Pure XP Water Filter Pitcher
Pitcher filter
Epic Pure XP Water Filter Pitcher
NSF-certified dual-layer filtration reduces 70+ contaminants including PFAS, lead, chlorine, microplastics, and bacteria.

The health risk for New Roads

lithium has been detected above EPA limits in this water system's recent tests. A certified filter designed for this contaminant type is strongly recommended.
  • lithium above limit.
lithium concentration (µg/L) September 2025
0 µg/L 10 µg/L 20 µg/L
11.700 µg/L
Detected
µg/L
10 µg/L
EPA limit
guideline
17% above limit
Comparison
vs. guideline
EPA limit: 10 µg/L | Your water: 11.700 µg/L
Certified Filters for New Roads Tap Water

lithium was detected above EPA limits. These filters are independently certified to reduce common drinking-water contaminants.

Water filter recommendation for New Roads tap water: Epic Pure XP Water Filter Pitcher
Pitcher filter
Epic Pure XP Water Filter Pitcher
NSF-certified dual-layer filtration reduces 70+ contaminants including PFAS, lead, chlorine, microplastics, and bacteria.
Water filter recommendation for New Roads tap water: Waterdrop G3P600 Reverse Osmosis System
Under-sink RO system
Waterdrop G3P600 Reverse Osmosis System
8-stage tankless RO system certified to NSF/ANSI 58, reduces 1,000+ contaminants including PFAS, lead, arsenic, fluoride, and nitrates.
Most elevated compounds
Compound Measurement EPA Limit Comparison
lithium
Tested: September 2023 · NEW ROADS WATER SYSTEM
11.700 µg/L 10 µg/L 17% above limit
lithium
Tested: September 2025 · Well #2 - Treated
9.350 µg/L 10 µg/L 94% of limit
lithium
Tested: September 2025 · Lakeland Well - Treated
9.010 µg/L 10 µg/L 90% of limit
View all tested compounds

NEW ROADS WATER SYSTEM · Tested: September 2023

Compound Measurement EPA Limit Comparison
lithium 11.700 µg/L 10 µg/L 17% above limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxS <0.003 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Lakeland Well - Treated · Tested: September 2025

Compound Measurement EPA Limit Comparison
lithium 9.010 µg/L 10 µg/L 90% of limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxS <0.003 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Well #2 - Treated · Tested: September 2025

Compound Measurement EPA Limit Comparison
lithium 9.350 µg/L 10 µg/L 94% of limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxS <0.003 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit
Primary source EPA UCMR5 (2023-2025)
Guideline source EPA drinking water standard (lithium: 10 µg/L)
Last tested September 2025
Last page update 2026-03-31

Check another ZIP code

    Data reflects publicly reported utility records from EPA datasets and local utility disclosures. This information is educational and not medical advice.

    Protect your water in New Roads → see certified filters