34610
Shady Hills, FL
Pasco County · Tampa-St. Petersburg-Clearwater, FL metro area
PCUD-PASCO COUNTY REGIONAL PWS

Is Shady Hills tap water safe to drink?

Higher concern
Last tested: May 2024
Source: EPA UCMR5 utility monitoring plus EPA Water Quality Portal well sampling (mapped to nearest ZIP). Last tested May 2024.
Townships:
  • Port Richey CCD, FL
  • Central Pasco CCD, FL
Community:
  • Spring Hill, FL

The short answer for Shady Hills

Shady Hills tap water has 5 contaminants above EPA guidelines, including PFBS at 2.9× the limit (tested April 2024). See the full compound-by-compound breakdown and filter recommendations.

The health risk for Shady Hills

PFAS ('forever chemicals') have been detected above EPA limits in this water system's most recent tests. These synthetic chemicals do not break down in the body and are linked to a range of health effects. A certified filter is strongly recommended.
  • PFBS, PFHpA, PFOS, PFPeA above limit.
PFBS concentration (µg/L) April 2024
0 µg/L 0.003 µg/L 0.01 µg/L
0.009 µg/L
Detected
µg/L
0.003 µg/L
EPA limit
guideline
187% above limit
Comparison
vs. guideline
EPA limit: 0.003 µg/L | Your water: 0.009 µg/L
Certified Filters for Shady Hills Tap Water

PFBS (a PFAS 'forever chemical') was detected above EPA limits. These filters are independently certified to reduce common drinking-water contaminants.

Water filter recommendation for Shady Hills tap water: Epic Pure XP Water Filter Pitcher
Pitcher filter
Epic Pure XP Water Filter Pitcher
NSF-certified dual-layer filtration reduces 70+ contaminants including PFAS, lead, chlorine, microplastics, and bacteria.
NSF/ANSI 42, 53, 401 & P473Removes 99.99% PFASMade in USABPA-free
Most elevated compounds
Compound Measurement EPA Limit Comparison
PFBS
Tested: April 2024 · Southeast WTP
0.009 µg/L 0.003 µg/L 187% above limit
PFPeA
Tested: May 2024 · Tampa Lakebridge Intertie
0.008 µg/L 0.003 µg/L 180% above limit
PFOS
Tested: April 2024 · Southeast WTP
0.008 µg/L 0.004 µg/L 102% above limit
PFBS
Tested: May 2024 · Tampa Lakebridge Intertie
0.004 µg/L 0.003 µg/L 40% above limit
PFHpA
Tested: May 2024 · Tampa Lakebridge Intertie
0.003 µg/L 0.003 µg/L 10% above limit
View all tested compounds

Tampa Lakebridge Intertie · Tested: Multiple dates

Compound Measurement EPA Limit Comparison
PFPeA 0.008 µg/L 0.003 µg/L 180% above limit
PFBS 0.004 µg/L 0.003 µg/L 40% above limit
PFHpA 0.003 µg/L 0.003 µg/L 10% above limit
PFHxA 0.006 µg/L 3 µg/L 0.2% of limit
PFBA 0.007 µg/L 6 µg/L 0.1% of limit
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Southeast WTP · Tested: April 2024

Compound Measurement EPA Limit Comparison
PFBS 0.009 µg/L 0.003 µg/L 187% above limit
PFOS 0.008 µg/L 0.004 µg/L 102% above limit
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Autumn Oaks WTP · Tested: April 2024

Compound Measurement EPA Limit Comparison
8:2 FTS 0.005 µg/L 0.005 µg/L 100% of limit
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Cross Bar 2W Crews Lake U Fldn Aq (CB-2W) · Tested: Multiple dates

Compound Measurement EPA Limit Comparison
Nitrite 0.004 mg/L 1000 mg/L 0.0% of limit
Nitrate + Nitrite 0.006 mg/L 1E+04 mg/L 0.0% of limit
Alkalinity, total 170.000 mg/L
Aluminum 36.300 µg/L
Ammonia 0.111 mg/L
Ammonia-nitrogen 0.099 mg/L
Boron 32.500 µg/L
Calcium 65.100 mg/L
Chloride 7.090 mg/L
Fluoride 0.050 mg/L
Iron 497.000 µg/L
Magnesium 2.350 mg/L
Manganese 9.400 µg/L
Nitrogen, mixed forms (NH3)... 0.140 mg/L
Organic carbon 1.750 mg/L
Orthophosphate 0.020 mg/L
Phosphorus 0.026 mg/L
Potassium 0.310 mg/L
Purge Volume 545.870 gal
Silica 8.240 mg/L
Sodium 4.080 mg/L
Strontium 95.400 µg/L
Sulfate 0.100 mg/L
Total dissolved solids 191.000 mg/L
True color 20.000 PCU

Gowers Corner POE · Tested: April 2024

Compound Measurement EPA Limit Comparison
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Little Rd. WTP · Tested: Multiple dates

Compound Measurement EPA Limit Comparison
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

One Pasco Center POE · Tested: April 2024

Compound Measurement EPA Limit Comparison
6:2 FTS 0.005 µg/L 0.005 µg/L 100% of limit
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Southwest WTP · Tested: Multiple dates

Compound Measurement EPA Limit Comparison
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

TBW-US 41 (Cypress Creek) Intertie · Tested: Multiple dates

Compound Measurement EPA Limit Comparison
4:2 FTS 0.003 µg/L 0.003 µg/L 100% of limit
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Water utilities serving ZIP 34610

Service area boundaries are approximate and based on state filings or modeled estimates. Contact your utility to confirm exact service at a specific address.

Modeled boundaries are shown with a dashed outline. Outlines appear when service-area boundary data is available for this ZIP.

Frequently Asked Questions about ZIP 34610 Tap Water

What contaminants are above EPA limits in ZIP 34610?

ZIP 34610 has 5 contaminants above EPA health guidelines in the latest available data, including PFBS at 2.9x the EPA guideline. The full table on this page lists every tested compound and its measured level.

Will boiling ZIP 34610 tap water remove PFBS?

No. Boiling does not remove PFAS, and the compounds can actually become more concentrated as water evaporates. To reduce PFAS at home, use a filter independently certified to NSF/ANSI P473 (activated-carbon pitcher or under-sink) or NSF/ANSI 58 (reverse osmosis).

Do basic pitcher filters remove PFBS?

Most basic pitcher filters are only certified to NSF/ANSI 42 or 53, which do not cover PFAS. Look for a filter independently certified to NSF/ANSI P473 (activated-carbon pitcher or under-sink) or NSF/ANSI 58 (reverse osmosis) on the spec sheet.

Who provides tap water in ZIP 34610?

Public records identify PCUD-PASCO COUNTY REGIONAL PWS as a primary water system associated with ZIP 34610. Service boundaries can vary by address, so confirm exact service with the utility.

When was ZIP 34610 tap water last tested?

The most recent test date used in this report is May 2024. EnviroClarity last refreshed this page on 2026-05-05.

Where can I find the official water quality report for ZIP 34610?

Every U.S. public water system is required to publish an annual Consumer Confidence Report (CCR). Contact PCUD-PASCO COUNTY REGIONAL PWS or visit their website for the latest official report covering ZIP 34610. The EPA also maintains a national CCR locator.

Primary source EPA UCMR5 (2023-2025) + EPA WQP (well monitoring near ZIP)
Guideline source EPA drinking water standard (PFBS: 0,003 µg/L)
Last tested May 2024
Last page update 2026-05-05

Check another ZIP code

    Data reflects publicly reported utility records from EPA datasets and local utility disclosures. This information is educational and not medical advice.

    Protect your water in Shady Hills → see certified filters