34786
Lake Butler, FL
Orange County · Orlando-Kissimmee-Sanford, FL metro area
DAVIS SHORES (CONSEC)

Is tap water in Southwest Orange CCD (34786) safe to drink?

Higher concern
Last tested: April 2025
Source: Official EPA UCMR5 federal monitoring data. Last tested April 2025.
Township:
  • Southwest Orange CCD, FL

The short answer for Southwest Orange CCD (34786)

Lake Butler tap water has PFOS above EPA guidelines at 1.1× the limit (tested October 2024). See the full report with all tested compounds and filter options.

The health risk for Lake Butler

PFAS ('forever chemicals') have been detected above EPA limits in this water system's most recent tests. These synthetic chemicals do not break down in the body and are linked to a range of health effects. A certified filter is strongly recommended.
  • PFOS above limit.
PFOS concentration (µg/L) October 2024
0 µg/L 0.004 µg/L 0.01 µg/L
0.005 µg/L
Detected
µg/L
0.004 µg/L
EPA limit
guideline
15% above limit
Comparison
vs. guideline
EPA limit: 0.004 µg/L | Your water: 0.005 µg/L
Certified Filters for Lake Butler Tap Water

PFOS (a PFAS 'forever chemical') was detected above EPA limits. These filters are independently certified to reduce common drinking-water contaminants.

Water filter recommendation for Lake Butler tap water: Epic Pure XP Water Filter Pitcher
Pitcher filter
Epic Pure XP Water Filter Pitcher
NSF-certified dual-layer filtration reduces 70+ contaminants including PFAS, lead, chlorine, microplastics, and bacteria.
NSF/ANSI 42, 53, 401 & P473Removes 99.99% PFASMade in USABPA-free
Most elevated compounds
Compound Measurement EPA Limit Comparison
PFOS
Tested: October 2024 · County Road 535 WTP
0.005 µg/L 0.004 µg/L 15% above limit
8:2 FTS
Tested: April 2025 · Conway Water Plant
0.005 µg/L 0.005 µg/L 100% of limit
8:2 FTS
Tested: October 2024 · Oak Meadows
0.005 µg/L 0.005 µg/L 100% of limit
6:2 FTS
Tested: October 2024 · Malcolm Road
0.005 µg/L 0.005 µg/L 100% of limit
8:2 FTS
Tested: February 2024 · Cypress Walk
0.005 µg/L 0.005 µg/L 100% of limit
View all tested compounds

County Road 535 WTP · Tested: October 2024

Compound Measurement EPA Limit Comparison
PFOS 0.005 µg/L 0.004 µg/L 15% above limit
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Conway Water Plant · Tested: April 2025

Compound Measurement EPA Limit Comparison
8:2 FTS 0.005 µg/L 0.005 µg/L 100% of limit
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Cypress Walk · Tested: February 2024

Compound Measurement EPA Limit Comparison
8:2 FTS 0.005 µg/L 0.005 µg/L 100% of limit
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Hidden Springs · Tested: October 2024

Compound Measurement EPA Limit Comparison
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Highland Water Plant · Tested: April 2025

Compound Measurement EPA Limit Comparison
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Hunters Creek · Tested: February 2024

Compound Measurement EPA Limit Comparison
8:2 FTS 0.005 µg/L 0.005 µg/L 100% of limit
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Kirkman Water Plant · Tested: April 2025

Compound Measurement EPA Limit Comparison
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Malcolm Road · Tested: October 2024

Compound Measurement EPA Limit Comparison
6:2 FTS 0.005 µg/L 0.005 µg/L 100% of limit
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Oak Meadows · Tested: October 2024

Compound Measurement EPA Limit Comparison
8:2 FTS 0.005 µg/L 0.005 µg/L 100% of limit
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Orangewood · Tested: February 2024

Compound Measurement EPA Limit Comparison
8:2 FTS 0.005 µg/L 0.005 µg/L 100% of limit
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Pine Hills Water Plant · Tested: April 2025

Compound Measurement EPA Limit Comparison
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Sky Lake Water Plant · Tested: April 2025

Compound Measurement EPA Limit Comparison
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Southern Regional · Tested: February 2024

Compound Measurement EPA Limit Comparison
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Southwest Water Plant · Tested: April 2025

Compound Measurement EPA Limit Comparison
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Vistana · Tested: February 2024

Compound Measurement EPA Limit Comparison
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Western Regional · Tested: Multiple dates

Compound Measurement EPA Limit Comparison
lithium <9.000 µg/L 10 µg/L Below limit
PFHxS <0.003 µg/L 0.004 µg/L Below limit
HFPO-DA <0.005 µg/L 0.01 µg/L Below limit
PFNA <0.004 µg/L 0.01 µg/L Below limit
PFHxA <0.003 µg/L 3 µg/L Below limit
PFBA <0.005 µg/L 6 µg/L Below limit
11Cl-PF3OUdS <0.005 µg/L 0.005 µg/L Below limit
4:2 FTS <0.003 µg/L 0.003 µg/L Below limit
6:2 FTS <0.005 µg/L 0.005 µg/L Below limit
8:2 FTS <0.005 µg/L 0.005 µg/L Below limit
9Cl-PF3ONS <0.002 µg/L 0.002 µg/L Below limit
ADONA <0.003 µg/L 0.003 µg/L Below limit
PFBS <0.003 µg/L 0.003 µg/L Below limit
PFDA <0.003 µg/L 0.003 µg/L Below limit
PFDoA <0.003 µg/L 0.003 µg/L Below limit
PFHpA <0.003 µg/L 0.003 µg/L Below limit
PFHpS <0.003 µg/L 0.003 µg/L Below limit
PFOA <0.004 µg/L 0.004 µg/L Below limit
PFOS <0.004 µg/L 0.004 µg/L Below limit
PFPeA <0.003 µg/L 0.003 µg/L Below limit
PFTrDA <0.007 µg/L 0.007 µg/L Below limit
PFUnA <0.002 µg/L 0.002 µg/L Below limit

Water utilities serving ZIP 34786

Service area boundaries are approximate and based on state filings or modeled estimates. Contact your utility to confirm exact service at a specific address.

Modeled boundaries are shown with a dashed outline.

Frequently Asked Questions about ZIP 34786 Tap Water

What contaminants are above EPA limits in ZIP 34786?

ZIP 34786 has PFOS above EPA health guidelines in the latest available data at 1.1x the EPA guideline. The full table on this page lists every tested compound and its measured level.

Will boiling ZIP 34786 tap water remove PFOS?

No. Boiling does not remove PFAS, and the compounds can actually become more concentrated as water evaporates. To reduce PFAS at home, use a filter independently certified to NSF/ANSI P473 (activated-carbon pitcher or under-sink) or NSF/ANSI 58 (reverse osmosis).

Do basic pitcher filters remove PFOS?

Most basic pitcher filters are only certified to NSF/ANSI 42 or 53, which do not cover PFAS. Look for a filter independently certified to NSF/ANSI P473 (activated-carbon pitcher or under-sink) or NSF/ANSI 58 (reverse osmosis) on the spec sheet.

Who provides tap water in ZIP 34786?

Public records identify DAVIS SHORES (CONSEC) as a primary water system associated with ZIP 34786. Service boundaries can vary by address, so confirm exact service with the utility.

When was ZIP 34786 tap water last tested?

The most recent test date used in this report is April 2025. EnviroClarity last refreshed this page on 2026-05-05.

Where can I find the official water quality report for ZIP 34786?

Every U.S. public water system is required to publish an annual Consumer Confidence Report (CCR). Contact DAVIS SHORES (CONSEC) or visit their website for the latest official report covering ZIP 34786. The EPA also maintains a national CCR locator.

Primary source EPA UCMR5 (2023-2025)
Guideline source EPA drinking water standard (PFTrDA: 0,007 µg/L)
Last tested April 2025
Last page update 2026-05-05

Check another ZIP code

    Data reflects publicly reported utility records from EPA datasets and local utility disclosures. This information is educational and not medical advice.

    Protect your water in Lake Butler → see certified filters