Goodyear tap water has 12 contaminants above EPA guidelines, including lithium at 33.5× the limit (tested January 2024). See the full compound-by-compound breakdown and filter recommendations.
The health risk for Goodyear
- lithium, PFBS, PFHxS, PFOA, PFOS, PFPeA above limit.
lithium was detected above EPA limits. These filters are independently certified to reduce common drinking-water contaminants.
Here's what actually removes PFAS from your water
The right filter eliminates PFAS at the tap. But not all filters do - and the type you choose matters for your home.
Common pitchers like Brita do not remove PFAS. You need a filter independently certified to NSF P473 (for pitcher filters) or NSF/ANSI 58 (for reverse osmosis systems). All three options below carry the relevant certification.
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| lithium Tested: January 2024 · EPDS012 |
335.000 µg/L | 10 µg/L | 3250% above limit |
| lithium Tested: April 2024 · EPDS022 |
85.100 µg/L | 10 µg/L | 751% above limit |
| lithium Tested: January 2024 · EPDS011 |
80.400 µg/L | 10 µg/L | 704% above limit |
| lithium Tested: April 2024 · EPDS003 |
75.600 µg/L | 10 µg/L | 656% above limit |
| lithium Tested: June 2024 · EPDS018 |
71.600 µg/L | 10 µg/L | 616% above limit |
View all tested compounds
EPDS018 · Tested: June 2024
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| lithium | 71.600 µg/L | 10 µg/L | 616% above limit |
| PFOS | 0.008 µg/L | 0.004 µg/L | 98% above limit |
| PFHxS | 0.006 µg/L | 0.004 µg/L | 53% above limit |
| PFOA | 0.005 µg/L | 0.004 µg/L | 20% above limit |
| PFBS | 0.003 µg/L | 0.003 µg/L | 10% above limit |
| PFNA | 0.004 µg/L | 0.01 µg/L | 43% of limit |
| HFPO-DA | <0.005 µg/L | 0.01 µg/L | Below limit |
| PFHxA | <0.003 µg/L | 3 µg/L | Below limit |
| PFBA | <0.005 µg/L | 6 µg/L | Below limit |
| 11Cl-PF3OUdS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 4:2 FTS | <0.003 µg/L | 0.003 µg/L | Below limit |
| 6:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 8:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 9Cl-PF3ONS | <0.002 µg/L | 0.002 µg/L | Below limit |
| ADONA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDoA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpS | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFPeA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFTrDA | <0.007 µg/L | 0.007 µg/L | Below limit |
| PFUnA | <0.002 µg/L | 0.002 µg/L | Below limit |
EPDS011 · Tested: January 2024
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| lithium | 80.400 µg/L | 10 µg/L | 704% above limit |
| PFPeA | 0.004 µg/L | 0.003 µg/L | 23% above limit |
| PFHxS | <0.003 µg/L | 0.004 µg/L | Below limit |
| HFPO-DA | <0.005 µg/L | 0.01 µg/L | Below limit |
| PFNA | <0.004 µg/L | 0.01 µg/L | Below limit |
| PFHxA | <0.003 µg/L | 3 µg/L | Below limit |
| PFBA | <0.005 µg/L | 6 µg/L | Below limit |
| 11Cl-PF3OUdS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 4:2 FTS | <0.003 µg/L | 0.003 µg/L | Below limit |
| 6:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 8:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 9Cl-PF3ONS | <0.002 µg/L | 0.002 µg/L | Below limit |
| ADONA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFBS | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDoA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpS | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFOA | <0.004 µg/L | 0.004 µg/L | Below limit |
| PFOS | <0.004 µg/L | 0.004 µg/L | Below limit |
| PFTrDA | <0.007 µg/L | 0.007 µg/L | Below limit |
| PFUnA | <0.002 µg/L | 0.002 µg/L | Below limit |
EPDS022 · Tested: April 2024
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| lithium | 85.100 µg/L | 10 µg/L | 751% above limit |
| PFBS | 0.006 µg/L | 0.003 µg/L | 87% above limit |
| PFHxS | <0.003 µg/L | 0.004 µg/L | Below limit |
| HFPO-DA | <0.005 µg/L | 0.01 µg/L | Below limit |
| PFNA | <0.004 µg/L | 0.01 µg/L | Below limit |
| PFHxA | <0.003 µg/L | 3 µg/L | Below limit |
| PFBA | <0.005 µg/L | 6 µg/L | Below limit |
| 11Cl-PF3OUdS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 4:2 FTS | <0.003 µg/L | 0.003 µg/L | Below limit |
| 6:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 8:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 9Cl-PF3ONS | <0.002 µg/L | 0.002 µg/L | Below limit |
| ADONA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDoA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpS | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFOA | <0.004 µg/L | 0.004 µg/L | Below limit |
| PFOS | <0.004 µg/L | 0.004 µg/L | Below limit |
| PFPeA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFTrDA | <0.007 µg/L | 0.007 µg/L | Below limit |
| PFUnA | <0.002 µg/L | 0.002 µg/L | Below limit |
EPDS003 · Tested: April 2024
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| lithium | 75.600 µg/L | 10 µg/L | 656% above limit |
| PFHxS | <0.003 µg/L | 0.004 µg/L | Below limit |
| HFPO-DA | <0.005 µg/L | 0.01 µg/L | Below limit |
| PFNA | <0.004 µg/L | 0.01 µg/L | Below limit |
| PFHxA | <0.003 µg/L | 3 µg/L | Below limit |
| PFBA | <0.005 µg/L | 6 µg/L | Below limit |
| 11Cl-PF3OUdS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 4:2 FTS | <0.003 µg/L | 0.003 µg/L | Below limit |
| 6:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 8:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 9Cl-PF3ONS | <0.002 µg/L | 0.002 µg/L | Below limit |
| ADONA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFBS | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDoA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpS | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFOA | <0.004 µg/L | 0.004 µg/L | Below limit |
| PFOS | <0.004 µg/L | 0.004 µg/L | Below limit |
| PFPeA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFTrDA | <0.007 µg/L | 0.007 µg/L | Below limit |
| PFUnA | <0.002 µg/L | 0.002 µg/L | Below limit |
EPDS012 · Tested: January 2024
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| lithium | 335.000 µg/L | 10 µg/L | 3250% above limit |
| PFHxS | <0.003 µg/L | 0.004 µg/L | Below limit |
| HFPO-DA | <0.005 µg/L | 0.01 µg/L | Below limit |
| PFNA | <0.004 µg/L | 0.01 µg/L | Below limit |
| PFHxA | <0.003 µg/L | 3 µg/L | Below limit |
| PFBA | <0.005 µg/L | 6 µg/L | Below limit |
| 11Cl-PF3OUdS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 4:2 FTS | <0.003 µg/L | 0.003 µg/L | Below limit |
| 6:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 8:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 9Cl-PF3ONS | <0.002 µg/L | 0.002 µg/L | Below limit |
| ADONA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFBS | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDoA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpS | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFOA | <0.004 µg/L | 0.004 µg/L | Below limit |
| PFOS | <0.004 µg/L | 0.004 µg/L | Below limit |
| PFPeA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFTrDA | <0.007 µg/L | 0.007 µg/L | Below limit |
| PFUnA | <0.002 µg/L | 0.002 µg/L | Below limit |
EPDS021 · Tested: January 2024
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| lithium | 55.200 µg/L | 10 µg/L | 452% above limit |
| PFHxS | <0.003 µg/L | 0.004 µg/L | Below limit |
| HFPO-DA | <0.005 µg/L | 0.01 µg/L | Below limit |
| PFNA | <0.004 µg/L | 0.01 µg/L | Below limit |
| PFHxA | <0.003 µg/L | 3 µg/L | Below limit |
| PFBA | <0.005 µg/L | 6 µg/L | Below limit |
| 11Cl-PF3OUdS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 4:2 FTS | <0.003 µg/L | 0.003 µg/L | Below limit |
| 6:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 8:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 9Cl-PF3ONS | <0.002 µg/L | 0.002 µg/L | Below limit |
| ADONA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFBS | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDoA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpS | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFOA | <0.004 µg/L | 0.004 µg/L | Below limit |
| PFOS | <0.004 µg/L | 0.004 µg/L | Below limit |
| PFPeA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFTrDA | <0.007 µg/L | 0.007 µg/L | Below limit |
| PFUnA | <0.002 µg/L | 0.002 µg/L | Below limit |
Water utilities serving ZIP 85338
Service area boundaries are approximate and based on state filings or modeled estimates. Contact your utility to confirm exact service at a specific address.
- GOODYEAR WATER DEPARTMENTAction advised
Frequently Asked Questions about ZIP 85338 Tap Water
What contaminants are above EPA limits in ZIP 85338?
ZIP 85338 has 12 contaminants above EPA health guidelines in the latest available data, including lithium at 33.5x the EPA guideline. The full table on this page lists every tested compound and its measured level.
Will boiling ZIP 85338 tap water remove lithium?
No. Boiling tap water does not remove lithium. Lithium is a dissolved mineral, so heat does not break it down and evaporation can actually concentrate it. Reverse osmosis (NSF/ANSI 58) is the most reliable at-home option for reducing lithium.
Do basic pitcher filters remove lithium?
Standard pitcher filters are not certified to reduce lithium. Reverse osmosis (NSF/ANSI 58) is the most widely available home option for reducing lithium in drinking water.
Who provides tap water in ZIP 85338?
Public records identify GOODYEAR WATER DEPARTMENT as a primary water system associated with ZIP 85338. Service boundaries can vary by address, so confirm exact service with the utility.
When was ZIP 85338 tap water last tested?
The most recent test date used in this report is June 2024. EnviroClarity last refreshed this page on 2026-05-04.
Where can I find the official water quality report for ZIP 85338?
Every U.S. public water system is required to publish an annual Consumer Confidence Report (CCR). Contact GOODYEAR WATER DEPARTMENT or visit their website for the latest official report covering ZIP 85338. The EPA also maintains a national CCR locator.
Check another ZIP code
Nearby ZIP reports
- 85323 - Gila Bend CCD, Avondale tap water report
- 85395 - Phoenix CCD, Goodyear tap water report
- 85392 - Villa de Paz, Avondale tap water report
- 85340 - Phoenix CCD, Buckeye tap water report
- 85396 - Wickenburg CCD, Buckeye tap water report
- 85353 - Tolleson, Phoenix tap water report
- 85307 - Phoenix, Glendale tap water report
- 85037 - Sheffield Place, Phoenix tap water report
Data reflects publicly reported utility records from EPA datasets and local utility disclosures. This information is educational and not medical advice.